Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Acta Obstet Gynecol Scand ; 101(2): 241-247, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35049047

RESUMO

INTRODUCTION: In this feasibility study, we hypothesize that the evaluation of cervical biomechanical strength can be improved if cervical length measurement is supplemented with quantitative elastography, which is a technique based on conventional ultrasound elastography combined with a force-measuring device. Our aims were to: (a) develop a force-measuring device; (b) introduce a cervical elastography index (CEI) and a cervical strength index (CSI; defined as cervical length × CEI); (c) evaluate how these indexes assess the cervical softening that takes place during normal pregnancy; and (d) how these indexes predict the cervical dilatation time from 4 to 10 cm. MATERIAL AND METHODS: An electronic force-measuring device was mounted on the handle of the transvaginal probe, allowing for force measurement when conducting elastography. The study group concerned with normal cervical softening included 44 unselected pregnant women. Outcomes were CEI and CSI at different gestational ages. The study group for labor induction included 26 singleton term pregnant women admitted for labor induction. Outcome was defined as cervical dilatation time from 4 to 10 cm. Elastography measured the changes in mean gray value (intensity) during manual compressions. Region of interest was set within the anterior cervical lip. RESULTS: We found that the mean of all variables regarding cervical softening decreased from early to late pregnancy: ie cervical length from 34 to 29 mm, CEI from 0.17 to 0.11 N, and CSI from 5.9 to 3.1 N mm. Moreover, the cervical dilatation time during labor induction was associated with CEI, although not statistically significantly (area under the ROC curve of 0.67), but not with the Bishop score, the cervical length, or the CSI. CONCLUSIONS: We propose that quantitative elastography based on changes in the intensity of the B-mode ultrasound recording, in combination with a force-measuring device on the handle of the vaginal probe, deserves further investigation as an approach for evaluation of cervical biomechanical strength.


Assuntos
Colo do Útero/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Ultrassonografia Pré-Natal , Adolescente , Adulto , Colo do Útero/diagnóstico por imagem , Desenho de Equipamento , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Valor Preditivo dos Testes , Gravidez , Trimestres da Gravidez , Nascimento Prematuro , Adulto Jovem
2.
PLoS One ; 15(10): e0240406, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33052935

RESUMO

BACKGROUND: Dystocia is one of the most common causes of cesarean section in nulliparous women. Studies have described the presence of vitamin D receptors in the myometrium, but it is still unclear whether vitamin D affects the contractility of the smooth muscles. We therefore aimed to determine the association between the vitamin D serum level at labor and the risk of dystocia. METHOD: We conducted a case-control study between January 2012 and June 2017. Cases were primiparous women, with spontaneous onset of labor, who gave birth by cesarean section due to dystocia. Controls were primiparous women with a spontaneous vaginal delivery. We included 60 women (30 cases and 30 controls) in the analysis. The differences between cases and controls were assessed using chi-squared test for categorical variables and two-sample t-test or unequal t-test for continuous variables, as appropriate, after evaluation of whether they followed the normal distributions. RESULTS: The mean serum 25-hydroxyvitamin D concentrations were 53.1nmol/l (95%CI; 45.2 to 60.9) among cases and 69.9nmol/l (95%CI; 57.5 to 82.4) among controls (P = 0.02). The mean plasma parathyroid hormone levels were 2.25 pmol/l and 2.38, respectively (P = 0.57). Even though 78% of all women reported taking a minimum of 10µg/day of vitamin D throughout pregnancy, 43% had vitamin D insufficiency, defined as serum 25-hydroxyvitamin D levels below 50nmol/l. CONCLUSIONS: In a Danish group of women having a cesarean section due to dystocia, we found decreased vitamin D levels.


Assuntos
Distocia/epidemiologia , Início do Trabalho de Parto/sangue , Deficiência de Vitamina D/epidemiologia , Vitamina D/análogos & derivados , Adulto , Estudos de Casos e Controles , Cesárea , Dinamarca/epidemiologia , Distocia/sangue , Distocia/etiologia , Feminino , Humanos , Idade Materna , Hormônio Paratireóideo/sangue , Gravidez , Vitamina D/sangue , Deficiência de Vitamina D/sangue
3.
J Med Case Rep ; 8: 156, 2014 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-24886611

RESUMO

INTRODUCTION: Hypomelanosis of Ito was originally described as a purely cutaneous disease. Extracutaneous manifestations were described later, forming a neurocutaneous syndrome including skeletal, muscular, ocular and central nervous system symptoms.Hypomelanosis of Ito is characterized by a depigmentation along the lines of Blaschko on the trunk and extremities in certain patterns.The aim of this article was to report another case and give an overview of the related orthopedic symptoms that have been previously described. It was also our wish to contribute with recommendations for consideration with regard to bandages on eczematous rashes, especially on clubfeet. CASE PRESENTATION: A one-and-a-half-month-old boy of Caucasian background born with talipes equinovarus, or clubfoot, on his right foot presented with an eczematous rash after surgical correction and plaster bandaging. CONCLUSIONS: It is the appearance of hypopigmentation, either alone or in combination with a congenital malformation, particularly central nervous system or musculoskeletal anomalies, which should form the basis of a presumptive diagnosis. This should then lead to further investigations and should always include skin biopsies and a test for chromosomal mosaicism.We report the case of a boy with a clinical picture consisting of a depigmented skin pattern, mental retardation, pes cavus, talipes equinovarus, clinodactyly, eczema, inverted cilia of the eye, strabismus, reduced hearing, ventral hernia, glomerulonephritis, missing testicles, leg length discrepancy with scoliosis, back pain and a syrinx.It is perhaps impossible to make any conclusions about extracutaneous symptoms. However, some symptoms such as retardation, cramps and seizures, delayed development and hypotonia cannot be ignored.Because of the possibility of creating an undesirable and long postoperative period with complications, it is very important to have this diagnosis in mind when deciding to do surgery or not if there are signs of dermatological problems before surgery. In this case, it could also be good clinical practice to test the patient's reaction to plaster or other bandages.


Assuntos
Anormalidades Múltiplas/patologia , Pé Torto Equinovaro/complicações , Hipopigmentação/complicações , Dorso , Humanos , Hipopigmentação/patologia , Lactente , Desigualdade de Membros Inferiores/complicações , Masculino , Escoliose/complicações , Pele/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...